On the usability of intramuscular EMG for prosthetic control: A Fitts’ Law approach

dc.contributor.authorKamavuako, Ernest N.
dc.contributor.authorScheme, Erik J.
dc.contributor.authorKevin B., Englehart
dc.date.accessioned2023-12-21T18:07:48Z
dc.date.available2023-12-21T18:07:48Z
dc.date.issued2014-10
dc.description.abstractPrevious studies on intramuscular EMG based control used offline data analysis. The current study investigates the usability of intramuscular EMG in two degree-of-freedom using a Fitts’ Law approach by combining classification and proportional control to perform a task, with real time feedback of user performance. Nine able-bodied subjects participated in the study. Intramuscular and surface EMG signals were recorded concurrently from the right forearm. Five performance metrics (Throughput, Path efficiency, Average Speed, Overshoot and Completion Rate) were used for quantification of usability. Intramuscular EMG based control performed significantly better than surface EMG for Path Efficiency (80.5 ± 2.4% vs. 71.5 ± 3.8%, P = 0.004) and Overshoot (22.0 ± 3.0% vs. 45.1 ± 6.6%, P = 0.01). No difference was found between Throughput and Completion Rate. However the Average Speed was significantly higher for surface (51.8 ± 5.5%) than for intramuscular EMG (35.7 ± 2.7%). The results obtained in this study imply that intramuscular EMG has great potential as control source for advanced myoelectric prosthetic devices.
dc.description.copyright© This manuscript version is made available under the CC-BY-NC-ND 4.0 license https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.identifier.urihttps://unbscholar.lib.unb.ca/handle/1882/37610
dc.language.isoen
dc.publisherElsevier
dc.relationDanish Agency for Science, Technology and Innovation
dc.relationNatural Sciences and Engineering Research Council of Canada
dc.relation.hasversionhttps://doi.org/10.1016/j.jelekin.2014.06.009
dc.rightshttp://purl.org/coar/access_right/c_abf2
dc.subject.disciplineElectrical and Computer Engineering
dc.titleOn the usability of intramuscular EMG for prosthetic control: A Fitts’ Law approach
dc.typejournal article
oaire.citation.endPage777
oaire.citation.issue5
oaire.citation.startPage770
oaire.citation.titleJournal of Electromyography and Kinesiology
oaire.citation.volume24
oaire.license.conditionhttp://creativecommons.org/licenses/by-nc-nd/4.0/
oaire.versionhttp://purl.org/coar/version/c_ab4af688f83e57aa

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Kamavuako et al. JEK 2014, Final Submission.pdf
Size:
744.46 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.13 KB
Format:
Item-specific license agreed upon to submission
Description:

Collections